Proof-of-concept of a robotic-driven photogrammetric scanner for intra-operative knee cartilage repair

Date: 01.04.2023

Healthcare Technology Letters


Abstract

This work presents a proof-of-concept of a robotic-driven intra-operative scanner designed for knee cartilage lesion repair, part of a system for direct in vivo bioprinting. The proposed system is based on a photogrammetric pipeline, which reconstructs the cartilage and lesion surfaces from sets of photographs acquired by a robotic-handled endoscope, and produces 3D grafts for further printing path planning. A validation on a synthetic phantom is presented, showing that, despite the cartilage smooth and featureless surface, the current prototype can accurately reconstruct osteochondral lesions and their surroundings with mean error values of 0.199 ± 0.096 mm but with noticeable concentration on areas with poor lighting or low photographic coverage. The system can also accurately generate grafts for bioprinting, although with a slight tendency to underestimate the actual lesion sizes, producing grafts with coverage errors of −12.2 ± 3.7, −7.9 ± 4.9, and −15.2 ± 3.4% for the medio-lateral, antero-posterior, and craneo-caudal directions, respectively. Improvements in lighting and acquisition for enhancing reconstruction accuracy are planned as future work, as well as integration into a complete bioprinting pipeline and validation with ex vivo phantoms.

BIB_text

@Article {
title = {Proof-of-concept of a robotic-driven photogrammetric scanner for intra-operative knee cartilage repair},
journal = {Healthcare Technology Letters},
pages = {59-66},
volume = {11},
keywds = {
biological tissues; biomedical imaging; surgery
}
abstract = {

This work presents a proof-of-concept of a robotic-driven intra-operative scanner designed for knee cartilage lesion repair, part of a system for direct in vivo bioprinting. The proposed system is based on a photogrammetric pipeline, which reconstructs the cartilage and lesion surfaces from sets of photographs acquired by a robotic-handled endoscope, and produces 3D grafts for further printing path planning. A validation on a synthetic phantom is presented, showing that, despite the cartilage smooth and featureless surface, the current prototype can accurately reconstruct osteochondral lesions and their surroundings with mean error values of 0.199 ± 0.096 mm but with noticeable concentration on areas with poor lighting or low photographic coverage. The system can also accurately generate grafts for bioprinting, although with a slight tendency to underestimate the actual lesion sizes, producing grafts with coverage errors of −12.2 ± 3.7, −7.9 ± 4.9, and −15.2 ± 3.4% for the medio-lateral, antero-posterior, and craneo-caudal directions, respectively. Improvements in lighting and acquisition for enhancing reconstruction accuracy are planned as future work, as well as integration into a complete bioprinting pipeline and validation with ex vivo phantoms.


}
doi = {10.1049/htl2.12054},
date = {2023-04-01},
}
Vicomtech

Parque Científico y Tecnológico de Gipuzkoa,
Paseo Mikeletegi 57,
20009 Donostia / San Sebastián (Spain)

+(34) 943 309 230

Zorrotzaurreko Erribera 2, Deusto,
48014 Bilbao (Spain)

close overlay

Behavioral advertising cookies are necessary to load this content

Accept behavioral advertising cookies